Point Pod Connect closed flush in a marble island, with only a slim silver ring showing

Guide · Trimless outlets · USA

Trimless Outlets: The Seamless Look on Walls and Countertops

A trimless outlet sits flush with no cover plate. How they work on a wall, and the countertop version: a pop-up that closes under a disc of your own stone.

By Seb Aroney, founder of Modern Power Solutions · Updated November 2026

Free shipping across the USAShips in 24 hoursUp to 4-year warranty1,800+ reviews

Quick answers

?What is a trimless outlet?An outlet with no cover plate, set flush with the wall. A mounting frame is mudded into the drywall and painted over, so only the outlet face shows.
?Are trimless, seamless and minimalist outlets the same thing?Near enough. All three describe outlets that sit level with the surface, with no raised plate around them. On a countertop, the same idea is a pop-up that hides when it’s closed.
?Is there a trimless outlet for a countertop?Yes: a pop-up with a stone top. Point Pod Connect closes flush under a disc of your own countertop, so only a slim ring shows. Press it and two outlets and USB rise 6 11/16″.
?When do you plan one?Before the surface is finished. On a wall, before the drywall is taped and painted. In a countertop, before the stone is cut: it needs 19″ clear below and a GFCI-protected outlet within 6 ft.
?Is Point Pod Connect allowed in a kitchen countertop?It’s ETL listed to UL 962A and marked “suitable for installation in a kitchen countertop surface”. On an inspected build, show your inspector the listing first; we’ll send it.

Wall or countertop

Trimless on the wall, and in the countertop

It’s the same idea in both places, with nothing raised around the outlet. How it’s done is different.

A standard outlet
ShowsThe outlet and a cover plateGoesWalls, above the countertopPlan itAny timeFitted byAn electrician
A trimless wall outlet
ShowsOnly the outlet face, level with the wallGoesDrywallPlan itBefore the drywall is taped and paintedFitted byAn electrician, then the drywall finisher
What we sellA stone-top pop-up
ShowsA slim ring and a disc of your countertopGoesCountertops and islandsPlan itBefore the countertop is cutFitted byYour countertop installer; it plugs into an outlet below

We don’t sell trimless wall outlets: pop-up outlets are all we do. For the wall, ask your electrician. For a countertop, the closest thing to trimless is a pop-up that closes flush; our hidden outlets guide ranks them by how much shows.

The countertop version

Point Pod Connect: a trimless outlet for the countertop

Closed, it disappears into the countertop. Press it, and you get two outlets and USB.

Closes flushClosed, the top sits flush with the countertop. Only a slim silver or black ring and the disc of your countertop show.
Your countertop on topThe top cup takes a 3.66″ disc of your own stone, quartz, porcelain or timber, so the closed unit matches the surface around it.
Press to raisePress the top and let go: a motor raises it 6 11/16″, with two tamper-resistant outlets and USB charging. Unplug everything and press again to lower it.
Plugs in belowA 6 ft cord runs to a GFCI-protected outlet inside the cabinet, so the unit itself needs no hardwiring.
Silver Point Pod Connect raised in a marble showroom island, showing two outlets and USB ports
OpenPress the top and it risesTwo outlets plus USB, in a marble islandPoint Pod Connect →
Point Pod Connect raised, with a disc of stone in its top cup
Stone topA disc of your own countertopGlued into the top cup, so it matches when closedStone-top guide →
Black Point Pod Connect raised on a dark stone kitchen island
BlackIn black, for dark stoneBlack ring and outletsPoint Pod Connect, black →
Hole4″ (102 mm)Cut clean and chip-free
Countertop½″ or thickerNo maximum
Clear below19″ (483 mm)Measured from the top surface
Insert3.66″ acrossUp to 1 3/16″ (30 mm) thick
Outlets2 × 15 ATamper-resistant, 1,875 W in total
USB15W or 65WTwo USB-C and USB-A, or two USB-C PD

In a kitchen countertop

Point Pod Connect is ETL listed to UL 962A and marked “suitable for installation in a kitchen countertop surface” after Intertek’s countertop spill test, and it plugs into a GFCI receptacle under the counter. It’s installed in kitchen islands every day. UL groups plug-in units with furniture power, though, so on an inspected build show your inspector the listing before the stone is cut; email us and we’ll send it. If hardwiring is required, Hubbell’s countertop receptacles (UL 498) are the alternative, without a stone top.

Kitchen island outlet code · Compare the listed pop-ups

Why go trimless

Why a trimless outlet suits a kitchen island

Nothing on the surfaceClosed, the countertop is uninterrupted: no plate and no cover, just your stone. It suits open-plan kitchens where the island is on show.
Power where you use itTwo outlets and USB at the island for small appliances, laptops and phones, instead of cords stretched from the wall.
Matches your countertopThe insert is usually the core cut out of the hole, so the pattern lines up with the countertop around it.
Tamper-resistant outletsBoth outlets are tamper-resistant, and the unit lowers out of sight when you’re done.

What owners say

“Our countertop is used in the top which makes it almost unnoticeable when not in use.”D. M. · Verified buyerPoint Pod Connect, silver
“We replaced our old clunky pop up power units that looked like they belonged in a classroom. These lay nearly flush with the counter and have far fewer crevices to clean.”Kate K. · Verified buyerV15 quad-sided, black

Planning one

Planning a trimless countertop outlet

1

Pick the spot. Where you use appliances, usually the end of the prep zone, with nothing below it: keep drawers and pipes clear.

2

Check the space. The countertop must be at least ½″ thick, with 19″ clear below, measured from the top, and a GFCI-protected outlet within 6 ft. No outlet there? A licensed electrician adds one.

3

Keep the core. Our 4″ Point Pod hole saw keeps the core whole at 3.66″, ready to become the insert. It can be up to 1 3/16″ thick.

4

Have it fitted. Your countertop installer cuts the hole, fits the collet and flange, and lowers the unit in. Never glue the unit: it must stay removable from below.

Questions

Trimless outlet FAQs

What is a trimless outlet?

An outlet installed flush with the wall, with no cover plate. A mounting frame is set into the drywall, then taped, mudded, sanded and painted, so only the outlet face shows. They’re also called flush or seamless outlets.

What’s the difference between a trimless outlet and a regular one?

A regular outlet sits behind a cover plate that stands proud of the wall. A trimless one has no plate: the wall finish runs right up to the outlet.

What are seamless or minimalist outlets?

Outlets designed so nothing stands out from the surface: trimless outlets on walls and, on countertops, pop-ups that close flush. Point Pod Connect goes furthest, hiding under a disc of your own countertop.

Can I add a trimless outlet to an existing wall?

Yes, but the drywall around the frame has to be taped, mudded, sanded and repainted, so it’s easiest before the walls are finished. Wiring it is a job for a licensed electrician.

Is there a trimless outlet for a kitchen island?

Yes. Point Pod Connect closes flush in the countertop under a disc of your own stone, then rises 6 11/16″ with two outlets and USB when you press it. It needs a 4″ hole and 19″ clear below, measured from the top.

Do you sell trimless wall outlets?

No. Pop-up outlets are all we do, so for the wall, ask your electrician. For the countertop, see Point Pod Connect.

Do I need an electrician for Point Pod Connect?

Not for the unit: it plugs into a GFCI-protected outlet under the countertop with its 6 ft cord. If there’s no outlet there, a licensed electrician needs to add one. Don’t use an extension cord.

Is Point Pod Connect approved for kitchen countertops?

It’s ETL listed to UL 962A and marked “suitable for installation in a kitchen countertop surface” after Intertek’s countertop spill test. It plugs into a GFCI receptacle below the counter. On an inspected build, show your inspector the listing first; we can send it.

Want the trimless look on your countertop?

Point Pod Connect comes in silver or black, with 15W or 65W USB. Builders and designers can order at trade prices.

Silver Point Pod Connect raised on a light stone kitchen counter
Back to blog
Seb Aroney, founder of Modern Power Solutions

About the author

Seb Aroney

Founder and Director, Modern Power Solutions

Seb has been developing pop-up outlets since 2013, and they're all Modern Power Solutions does: one specialist range for kitchens, islands and offices, sold across Australia, the US and the UK, with support and warranty handled by our own team.