White V3C pop-up outlet raised on a marble kitchen island

Install guide · Kitchen islands · USA

How to Install a Pop-Up Outlet in a Kitchen Island

Hole sizes by model, the tools you need and six steps, plus how to get power to the island and when you need an electrician.

By Seb Aroney, founder of Modern Power Solutions · Updated November 2026

Quick answers

?How do I install a pop-up outlet in a kitchen island?Cut a hole, drop it in, tighten it from below. Check the space under the countertop, cut the hole size in your manual, lower the unit in, tighten its locking ring underneath, then plug it in and test it. The six steps.
?What size hole do I need?It depends on the model: 3¾ in for the V3C, 4 in for the V16 and Point Pod Connect, 3.47–3.63 in for Hubbell’s Dual-Sided. Always cut to the template in the manual.
?Do I need an electrician?Not for a plug-in pop-up if there’s already a GFCI-protected outlet in the cabinet. Adding that outlet, or wiring in a hardwired pop-up, is fixed wiring for a licensed electrician.
?How do I get power to the island?Plan it before the countertop goes on. An electrician usually brings power up through the floor or across from a nearby cabinet to a GFCI-protected outlet inside the island.
?Can it go in quartz or granite?Yes. Stone, quartz and porcelain need a diamond core bit with water cooling, so your countertop fabricator may prefer to cut the hole.

Before you cut

Check the space under the counter first

Countertop thicknessEach model has a maximum: 1 15/16 in for the V16, 2⅜ in for the V3C. Point Pod Connect has no maximum but needs at least ½ in.
Clear depth belowMeasured down from the top of the countertop: 13.8 in for the V16, 15¾ in for the V3C, 19 in for Point Pod Connect. Keep drawers, shelves and pipes out of it.
An outlet within reachPlug-in models need a GFCI-protected outlet in the cabinet within reach of the cord: 6 ft on the V3C and Point Pod Connect, 5 ft on the V16. No extension cords.
The right spotWhere you use small appliances, clear of the sink, back from the edge where people sit. Under the 2023 NEC, an island outlet goes in the countertop or above it, not on the cabinet side. The code guide.

Hole sizes

Hole size and depth by model

Download the manual for yours: each one has a printable cut-out template.

Point Pod ConnectPlug-inPoint Pod Connect4 in (102 mm) hole · countertop at least ½ in, no maximum · 19 in (483 mm) clear below · 6 ft cord to a GFCI outletInstalls differently (see below). Watch the install video.Install manual · PDF
V3C motorizedPlug-inV3C motorized3¾ in (95 mm) hole · countertop up to 2⅜ in (60 mm) · 15¾ in (400 mm) clear below · 6 ft cordInstall manual · PDF
V16 with lightPlug-inV16 with light4 in (102 mm) hole · countertop up to 1 15/16 in (50 mm) · 13.8 in (350 mm) clear below · 5 ft cordInstall manual · PDF
Hubbell Dual-SidedHardwiredHubbell Dual-Sided3.47–3.63 in hole (flush mount: 4 in counterbore) · 4.7 in body below the countertop · wired in by an electricianInstall guide · PDFSpec sheet · PDF
Hubbell Tri-PowerHardwiredHubbell Tri-PowerAbout 4 in hole · 5.6 in body below the countertop · wired in by an electricianWatch the install video.Install guide · PDFSpec sheet · PDF

Figures from each model’s install manual or spec sheet. Clear depth is measured down from the top of the countertop.

Tools

What you’ll need

A drill and a hole saw in your model’s size. Stone, quartz and porcelain need a diamond core bit with water cooling. We sell the 4 in diamond hole saw for Point Pod Connect.

Tape measure, pencil and masking tape. Tape around the hole helps stop the edge chipping.

The cut-out template from your manual, printed at 100% (check its scale bar first).

Safety glasses and a dust mask.

For Point Pod Connect: silicone, two-part epoxy (stone) or screws (wood or laminate) for the mounting flange, and a disc of your countertop for the top.

Step by step

Install it in six steps

These are the steps in our manuals for plug-in pop-ups like the V3C and V16. Point Pod Connect fits differently (below), and Hubbell’s hardwired units follow Hubbell’s install guide.

1

Check the space. Confirm the countertop thickness, the clear depth below and an outlet within reach of the cord, using your model’s figures.

2

Mark the hole. Tape the template where the unit will sit, mark the center and trace the cut line.

3

Cut the hole. Drill slowly and steadily with the hole saw square to the surface, then clean up the dust and any sharp edges.

4

Lower the unit in. Unscrew the locking ring from the body, then lower the unit through the hole until the flange sits flat on the countertop.

5

Tighten it from below. Screw the locking ring up the body and hand-tighten it against the underside of the countertop. Don’t over-tighten.

6

Plug in and test. Route the cord so it can’t catch as the unit moves, plug it in, then raise and lower it twice and check every outlet and USB port.

Installing Point Pod Connect

Point Pod Connect closes flush under a disc of your own countertop, so it’s held by a mounting flange instead of a locking ring:

Make the insert: a 3.66 in (93 mm) disc of your countertop, up to 1 3/16 in (30 mm) thick, test-fitted in the top cup.

Cut a 4 in hole and silicone the hole ring (outer collet) in, flush with the top.

Fix the mounting flange underneath: two-part epoxy on stone, quartz or porcelain, screws on wood or laminate.

Drop the unit in and tighten the fastening clip onto the flange. Never glue the unit itself: it must stay removable.

Glue the insert in with silicone, plug in and allow up to a minute to start. The first press moves it down.

Power and wiring

Plug-in or hardwired, and who does the wiring

Plug-in: you can fit itThe V3C, V16 and Point Pod Connect come with a cord and plug. Each plugs into a GFCI-protected outlet inside the cabinet, so if that outlet is already there you can install the unit yourself.
Hardwired: an electricianHubbell’s countertop receptacles are wired into a GFCI-protected circuit by an electrician, following Hubbell’s install guide. The simplest choice when a new build or remodel is being inspected.

Point Pod Connect is ETL listed to UL 962A and marked “suitable for installation in a kitchen countertop surface” after Intertek’s countertop spill test, and it’s installed in kitchen islands every day. UL groups plug-in units with furniture power, though, so on an inspected build show your inspector the listing before the countertop is cut. Email us and we’ll send it. If hardwiring is required, choose a Hubbell. Compare the listed pop-ups.

Getting power to the island

Plan it before the countertop goes on. Power usually comes up through the floor or across from a nearby cabinet.

Fixed wiring is for a licensed electrician: that includes a new outlet inside the island, under the NEC and local code.

GFCI protection. Receptacles serving kitchen countertops need it, so a plug-in pop-up plugs into a GFCI receptacle or a GFCI-protected circuit.

No outlet yet? Under the 2023 NEC, an island without one needs provision for adding one later, such as a box or conduit.

No extension cords. Plug the pop-up straight into the outlet below.

Questions

Installation FAQs

How do you install an outlet in a kitchen island?

For a pop-up: check the space below, cut the hole your manual gives, lower the unit in, tighten it from below, then plug it into a GFCI-protected outlet in the island and test it. If the island has no outlet yet, a licensed electrician adds one first.

What size hole does a pop-up outlet need?

3¾ in (95 mm) for the V3C, 4 in (102 mm) for the V16 and Point Pod Connect, 3.47–3.63 in for the Hubbell Dual-Sided and about 4 in for the Tri-Power. Each manual has a printable cut-out template.

Can I install a pop-up outlet in a quartz countertop?

Yes. Quartz, granite and porcelain need a diamond core bit with water cooling. Many people have their countertop fabricator cut the hole, and for Point Pod Connect we recommend a professional countertop installer.

Do pop-up outlets need an electrician?

Plug-in pop-ups don’t, if there’s already a GFCI-protected outlet in the cabinet. A new outlet, or a hardwired pop-up like Hubbell’s, is fixed wiring for a licensed electrician.

Does a kitchen island pop-up need GFCI?

Yes. Receptacles serving kitchen countertops need GFCI protection. A plug-in pop-up must plug into a GFCI receptacle or a GFCI-protected circuit.

How do I install a Point Pod?

Point Pod Connect needs a 4 in hole in a countertop at least ½ in thick, with 19 in clear below. The hole ring is siliconed in, the mounting flange is fixed underneath, then the unit drops in and clips to the flange. Never glue the unit itself.

Can I put the outlet on the side of the island instead?

Under the 2023 NEC, an outlet can’t serve the island countertop from the cabinet side. It goes in the countertop, using a pop-up listed for countertops, or on or above it.

How much space does a pop-up need under the countertop?

From a 4.7 in body for the Hubbell Dual-Sided to 19 in clear for Point Pod Connect, measured down from the top of the countertop. Check it against drawers, the sink and the dishwasher.

Can you help me choose a spot or a model?

Yes. Email us a photo or plan of your kitchen at Contact@ModernPower.Solutions and we’ll suggest a spot and a model.

Pick the pop-up for your island

Answer three questions in our island finder, or compare the pop-ups listed for countertops side by side.

White V3C pop-up outlet raised on a marble countertop
Back to blog
Seb Aroney, founder of Modern Power Solutions

About the author

Seb Aroney

Founder and Director, Modern Power Solutions

Seb has been developing pop-up outlets since 2013, and they're all Modern Power Solutions does: one specialist range for kitchens, islands and offices, sold across Australia, the US and the UK, with support and warranty handled by our own team.