Point Pod Connect UL Certification: The UL 962A Listing Explained
What Point Pod Connect is listed to, what UL 962A asks of a countertop unit, and what to show your inspector before the countertop is cut.
By Seb Aroney, founder of Modern Power Solutions · Updated November 2026
Quick answers
The listing
What Point Pod Connect is listed to
Point Pod Connect is ETL listed to UL 962A and marked “suitable for installation in a kitchen countertop surface” after Intertek’s countertop spill test. It plugs into a GFCI receptacle under the counter, so the unit itself needs no hardwiring, and it’s installed in kitchen islands every day. Email us and we’ll send the listing details.
Point Pod Connect, silver (PPCV815)Install and user manual MPS-UM-PPCV815-USThe listing is in its Compliance and Certification section, and both marking lines are in its safety instructions.Manual · PDF
Point Pod Connect, black (PPCV815B)Install and user manual MPS-UM-PPCV815B-USThe same listing and marking lines, for the black models.Manual · PDFUL 962A
UL 962A and UL 498, explained
UL 962A is the UL standard for furniture power distribution units, and it has its own requirements for units installed in kitchen and bathroom countertops. A countertop pop-up gets its listing one of two ways, depending on how it’s powered:
Looking for the standard itself? UL Standards & Engagement publishes UL 962A at shopulstandards.com. Many of its standards can be read there free, view-only, once you register; a downloadable or printed copy is paid.
Countertop tests
Why it’s marked for kitchen countertops
UL or ETL?
Is an ETL listing as good as UL?
Yes, as a mark. Intertek (the ETL mark) and UL are both on OSHA’s list of nationally recognized testing laboratories, and either can test a product and list it to a UL standard. Point Pod Connect is listed to UL 962A by Intertek, so it carries the ETL Listed mark rather than UL’s.
What matters to an inspector is the standard it’s listed to and whether it’s marked for countertop use, not which lab did the testing.
Inspection
On an inspected build
Before the countertop is cut, email us and we’ll send the listing. Show it to your inspector with the install manual.
Plan the GFCI receptacle. Point Pod Connect plugs into a GFCI-protected outlet under the counter, within reach of its 6 ft cord. If there isn’t one, a licensed electrician fits it; don’t use an extension cord.
Put it in the countertop. Under the 2023 NEC, an outlet can’t serve an island countertop from the cabinet side.
If hardwiring is required, choose a Hubbell countertop receptacle, listed to UL 498 and wired in by your electrician.
Plug-in units like Point Pod Connect are installed in kitchen islands every day. UL groups them with furniture power, though, so a few inspectors ask for a hardwired assembly on a built-in island.
Shop
Listed pop-ups for a kitchen island
HardwiredHubbell Dual-SidedcULus listed for countertops. 15 A or 20 A, with one outlet on each side.
HardwiredHubbell Tri-PowerUL listed for countertops. Outlet plus USB-A, USB-C and Qi wireless charging.
Plug-inPoint Pod ConnectETL listed to UL 962A, marked for kitchen countertops. Motorized, and hides under a disc of your own stone.Point Pod Connect comes in silver or black, with 15W or 65W USB. Hubbell’s come in 15 A or 20 A.
Planning a Point Pod Connect island?
Ask for the listing before the countertop is cut, and we’ll send it with the install manual. Point Pod Connect ships free across the USA.

Questions
Point Pod Connect listing FAQs
Is Point Pod Connect UL certified?
It’s listed to a UL standard, UL 962A, by Intertek (the ETL mark) rather than by UL itself, and to CSA C22.2 No. 308 for Canada. Intertek and UL are both nationally recognized testing laboratories.
What is UL 962A?
The UL standard for furniture power distribution units. It has its own requirements for units installed in kitchen and bathroom countertops, including a spill test and tamper-resistant outlets. Plug-in countertop pop-ups like Point Pod Connect are listed to it.
What does UL 962A require for a kitchen countertop unit?
Among other things: a spill test, with salt water poured over the raised unit and electrical safety checks straight after; tamper-resistant outlets (clause SC4.3); and the marking “suitable for installation in a kitchen countertop surface”, with a warning that it must connect to a GFCI receptacle or GFCI branch circuit.
Where can I read UL 962A for free?
UL Standards & Engagement publishes it at shopulstandards.com. Many of its standards can be read there free, view-only, once you register; a downloadable or printed copy is paid. We can’t share the standard itself, but we’ll send Point Pod Connect’s listing details.
What’s the difference between UL 962A and UL 498?
UL 962A covers furniture power distribution units, which plug in with a cord, like Point Pod Connect. UL 498 covers plugs and receptacles, including hardwired pop-up receptacle assemblies for countertops, like Hubbell’s.
Is an ETL listing as good as UL?
Yes, as a mark. Intertek (ETL) and UL are both on OSHA’s list of nationally recognized testing laboratories, and either can list a product to a UL standard. What matters to an inspector is the standard it’s listed to and whether it’s marked for countertop use.
Do you make custom UL 962A furniture power units?
No. We sell ready-made pop-ups rather than custom units. Point Pod Connect is listed to UL 962A, and fabricators, builders and furniture makers can order it at trade prices.
Does Point Pod Connect need a GFCI?
Yes. Its marking says it must be connected to a GFCI receptacle or a GFCI branch circuit, so it plugs into a GFCI-protected outlet under the counter, within reach of its 6 ft cord.
Is Point Pod Connect approved for kitchen countertops?
It’s ETL listed to UL 962A and marked “suitable for installation in a kitchen countertop surface” after Intertek’s countertop spill test. It plugs into a GFCI receptacle below the counter. On an inspected build, show your inspector the listing first; we can send it.
Sources
- OSHA: current list of nationally recognized testing laboratories
- UL Standards & Engagement: standards shop and Digital View
General information, not legal advice. Local codes vary and your inspector has the final say.