The Point Pod: How It Works, Models and Installation
A motorized pop-up outlet that hides under a disc of your own countertop. In the US it’s Point Pod Connect: how it works, which model to pick and how it’s installed.
By Seb Aroney, founder of Modern Power Solutions · Updated November 2026
Quick answers
How it works
A pop-up outlet that disappears into the countertop





Point Pod is designed and engineered in Australia by Point Pod, and its countertop-insert design won a Good Design Award in 2019. It has been sold in the US as Point Pod Connect since 2022.
Models
Point Pod Connect: silver or black
Two colors, each with 15W or 65W USB. Every model takes the same 4″ hole and the same disc of countertop.
Plug-inPoint Pod Connect, silverSilver shell and white outlets around a disc of your countertop.
Plug-inPoint Pod Connect, blackBlack shell and black outlets, for dark granite and quartz.
4-Inch Hole Saw for Point PodDiamond rim, 5/8-11 thread. Cuts the 4″ hole and keeps the core for the insert.15W or 65W USB?
Everything else is the same on all four: the two outlets, the size and the installation. Model numbers, sizes and manuals.
Searching for the Point Pod Multi or Compact? Those are the Australian models, with Australian power points, and they aren’t sold in the US.
Installing it
How a Point Pod is installed
Have a professional countertop installer cut the hole and fit it. The six steps from the install manual:
Check the space. The countertop must be at least ½″ thick, with 19″ clear below (measured from the top surface) and 6 5/16″ across for the flange. Keep drawers and pipes clear, and have a GFCI-protected outlet within 6 ft.
Make the insert. Cut a 3.66″ (93 mm) disc of your countertop, up to 1 3/16″ thick, and test-fit it in the top cup. Our 4″ hole saw keeps the core from the hole whole for this.
Cut the hole. A clean, chip-free 4″ hole, using the template in the manual. Stone and quartz need a diamond core bit with water cooling, or a water jet.
Fit the collet and flange. Silicone the outer collet into the hole, flush with the top. Underneath, fix the mounting flange around it: two-part epoxy on stone, screws on timber.
Lower the unit in. Feed it down through the collet until the top sits flush, then tighten the fastening clip onto the flange. Never glue the unit: it must stay removable.
Glue in the insert and test. Silicone the disc into the cup, lining up the pattern. Once it’s set, plug in and allow up to a minute to start: the first press moves it down, the next raises it.
Specs
Point Pod Connect at a glance
From the install manual. Full dimensions, both manuals and the model numbers are in the PPCV815 and PPCV815B guide.
Kitchen countertops
Is it allowed in a kitchen countertop?
Point Pod Connect is ETL listed to UL 962A and marked “suitable for installation in a kitchen countertop surface” after Intertek’s countertop spill test. It plugs into a GFCI receptacle under the counter, and it’s installed in kitchen islands every day.
UL groups plug-in units with furniture power, though, so on an inspected build show your inspector the listing before the countertop is cut; email us and we’ll send it. If hardwiring is required, Hubbell’s countertop receptacles (UL 498) are the alternative.
Everyday use
Living with a Point Pod
Questions
Point Pod FAQs
What is a Point Pod?
A motorized pop-up outlet designed and engineered in Australia by Point Pod. Its top holds a disc of your own countertop, so when it’s closed only a slim ring shows. In the US it’s sold as Point Pod Connect.
How do you install a Point Pod?
Cut a 4″ hole, silicone the outer collet into it and fix the mounting flange underneath. Then lower the unit in, tighten its fastening clip, glue a disc of your countertop into the top and plug it into a GFCI-protected outlet below. Have a professional countertop installer cut the hole.
What size hole does a Point Pod need?
4″ (102 mm), cut clean and chip-free. Underneath, allow 6 5/16″ (160 mm) across for the mounting flange and 19″ (483 mm) of clear depth, measured from the top of the countertop.
What is the Point Pod mounting flange?
The round bracket fixed under the countertop around the hole, with two-part epoxy on stone or screws on timber. The unit has no lip on top, so the flange and its fastening clip are what hold it in place.
Can it go in stone on a plywood sub top?
Yes. The mounting flange can be screwed and glued to the plywood; it’s a common setup. If the plywood can easily be cut away around the hole before the stone goes on, epoxying the flange straight to the stone is a little better.
Is the Point Pod spring-loaded?
No. It’s motorized: the built-in motor raises and lowers it when you press and release the top.
Do I need an electrician?
Not for the unit: it plugs into a GFCI-protected outlet under the countertop with its 6 ft cord. If there’s no outlet there, a licensed electrician needs to add one. Don’t use an extension cord.
Is there a Point Pod Multi or Compact in the US?
No. The Multi, Compact and Boardroom are the Australian models, with Australian power points. In the US it’s Point Pod Connect, with two US outlets and USB.
Is Point Pod Connect approved for kitchen countertops?
It’s ETL listed to UL 962A and marked “suitable for installation in a kitchen countertop surface” after Intertek’s countertop spill test. It plugs into a GFCI receptacle below the counter. On an inspected build, show your inspector the listing first; we can send it.
How long is the warranty?
24 months, parts and labor. Eligible purchases can be extended to up to four years; conditions apply.