How Do Pop-Up Outlets Work? Spring-Assisted, Motorized and Manual
A pop-up outlet hides in a round hole in your countertop and rises when you need it. Here’s how each type lifts, how it’s fitted and how it gets power.
By Seb Aroney, founder of Modern Power Solutions · Updated November 2026
Quick answers
Three ways they rise
Spring-assisted, motorized and manual
Every pop-up outlet is a column of outlets that slides up and down inside the countertop. What differs is how it lifts.
A gas strut is pressurized when it’s pushed down. Pressing the top releases it, and pushing it back down firmly sets it again for next time. The V16 rises 8 3/8 in; the four-sided V15 rises 3 1/8 in.
Motorized models ignore an accidental touch. The V3C only moves after a 3-second hold, so a phone on the lid won’t set it off, and it goes back to sleep after a few minutes. The V3C and Point Pod Connect stop if something blocks them.
Wireless charging isn’t tied to the type. The spring-assisted V16 and V15 (USB and Qi model) have wireless charging tops, and so does the motorized V3C. Point Pod Connect charges from USB instead.
Installation
How a pop-up outlet sits in the countertop
Lid and flange: closed, only these show on the countertop, and the flange covers the edge of the hole.
Countertop: each model has a maximum thickness: 2 3/8 in for the V3C, about 2 in for the V16.
Locking ring: screws up the body from underneath and clamps the unit to the countertop.
Body: hangs in the cabinet and slides up and down, so keep the space below it clear.
Cord: plug-in models plug into an outlet in the cabinet; hardwired models are wired in instead.
Raised: the column of outlets comes up above the countertop: 6 7/16 in on the V3C, 8 3/8 in on the V16.
Clear space below: measured from the top of the countertop. Check it before you cut: 15 3/4 in for the V3C, 19 in for Point Pod Connect.
Fitting one, step by step
Check the space. Measure the countertop thickness and the clear space below, and make sure there’s an outlet within reach of the cord.
Cut the hole. Use the cut-out template in the manual and a hole saw of the right size. Stone, quartz and porcelain need a diamond core bit with water cooling.
Take off the locking ring. Unscrew it from the body and set it aside.
Drop the unit in. Feed the body down through the hole until the flange sits flat on the countertop.
Tighten the ring from below. Screw it back up the body and tighten it by hand against the underside.
Plug in and test. Plug it into the outlet below, raise it, check the outlets and USB ports, then lower it.
Point Pod Connect fits differently: it closes flush with your countertop, with a disc of your own countertop in its top cup, so only a slim ring and the insert show. It drops through a 4 in hole and is held from underneath by a mounting flange, in countertops from ½ in to over 5 in thick.
Watch how to install Point Pod Connect on YouTube.
Before you cut
Hole size and space below, by model
Plug-inV3C motorized3 3/4 in (95 mm) hole · countertop up to 2 3/8 in · 15 3/4 in clear belowManual · PDF
Plug-inV15 spring-assisted3 1/8 in (80 mm) hole · countertop up to 3 5/16 in · 11 in clear belowManual · PDF
Plug-inV16 spring-assisted4 in (102 mm) hole · countertop up to 1 15/16 in · 13 13/16 in clear belowManual · PDFFigures are from each model’s manual. Clear space is measured from the top of the countertop; leave extra room for the cord and plug.
Power
Plug-in or hardwired
Point Pod Connect is ETL listed to UL 962A and marked “suitable for installation in a kitchen countertop surface” after Intertek’s countertop spill test, and plugs into a GFCI receptacle under the counter. Plug-in units like it are installed in kitchen islands every day. UL groups them with furniture power, though, so on an inspected build show your inspector the listing first (email us and we’ll send it), or choose a Hubbell if hardwiring is required. More in our kitchen island outlet code guide.
Shop
Our pop-up outlets, by type
Plug-inV16 with lightTwo outlets, 65W USB-C, a wireless charging top and a dimmable light.
Plug-inV3C motorizedTwo outlets, USB-A, USB-C and a wireless charging lid.
Plug-inPoint Pod ConnectTwo tamper-resistant outlets and USB; closes flush under a disc of your countertop.
HardwiredHubbell Dual-Sided15 A or 20 A, wired in by an electrician on a GFCI-protected circuit.Not sure which one fits?
Answer three questions in our model finder, or browse every pop-up outlet we sell in your country.

Questions
Pop-Up Outlets: FAQs
How do pop-up outlets work?
A pop-up outlet is a column of outlets that sits in a round hole in the countertop, with only its top showing. Press it and a gas strut lifts it (spring-assisted), or a motor raises it (motorized). Plug in, then push or press it back down.
Spring-assisted or motorized: which is better?
Motorized models are the most convenient: a touch raises and lowers them, and Point Pod Connect closes flush with your countertop. Spring-assisted models like the V15 and V16 rise on their own with no motor.
Do pop-up outlets need an electrician?
Plug-in models don’t, if there’s already an outlet under the counter. Adding a new outlet is fixed wiring for a licensed electrician, and hardwired assemblies like Hubbell’s are wired in by one.
Can a pop-up outlet go in a kitchen countertop?
The NEC only allows a receptacle in a countertop if it’s listed for countertop use. Hubbell’s hardwired assemblies are cULus listed for countertops; Point Pod Connect is ETL listed to UL 962A and marked “suitable for installation in a kitchen countertop surface”. On an inspected build, show your inspector the listing first. See the kitchen island outlet code guide.
What size hole does a pop-up outlet need?
3 1/8 in (80 mm) for the V15, 3 3/4 in (95 mm) for the V3C, and 4 in for the V16 and Point Pod Connect. Each manual has a printable cut-out template.
How much space do they need under the counter?
From 11 in (V15) to 19 in (Point Pod Connect): 13 13/16 in for the V16 and 15 3/4 in for the V3C, measured from the top of the countertop.
Can pop-up outlets be used in offices?
Yes, on indoor desks, conference tables and counters: the V3C and V15 are made for kitchen and office countertops. Fitting them on a project? See our trade pricing.