This guide covers Australia. For the US, see our kitchen island outlet code guide.

Pop up power point raised on a white stone kitchen benchtop

Legal guide · Australia

Are Pop Up Power Points Legal in Australia? The Rules Explained

Where a pop up power point can go in your kitchen, what makes a model legal to sell, and who is allowed to install it, under the current Wiring Rules (AS/NZS 3000:2018).

By Seb Aroney, founder of Modern Power Solutions · Updated November 2026

Quick answers

?Are they legal?Yes, when the model is approved for Australia, it’s outside the sink and cooktop zones, and a licensed electrician does any wiring.
?How far from the sink?At least 150 mm from the side of a sink of 40 litres or less. Bigger sinks and tubs: 0.5 m.
?And the cooktop?At least 150 mm from the edge of the cooktop.
?Do I need an RCD?Yes. The circuit your pop up uses needs RCD (safety switch) protection.

Placement

How far from the sink and cooktop

1 2 3 150 mm
1

Clear benchtop: outside both zones, at the end of your prep area.

2

Sink zone: no power point within 150 mm of the side of a sink of 40 L or less (0.5 m for bigger sinks and tubs).

3

Cooktop: no power point within 150 mm of the edge of the cooktop.

Tool

How far from your sink?

The zone depends on how much the sink holds. The capacity is on its spec sheet.

Sink of 40 litres or less

  • Keep the power point at least 150 mm from the side of the sink.
  • The zone also runs 0.4 m above the sink, so no power points on a splashback directly above it.

Sink or tub over 40 litres

  • Keep the power point at least 0.5 m from the side of the sink or tub.
  • The zone runs 1 m above it.

Distances are measured from the side of the sink. On an island, the best spot is usually the end of your prep area, back from where people sit.

Before you buy

What makes a pop up power point legal to sell

Power points, including pop ups with a cord that are fixed into a bench or desk, are Level 3 electrical equipment, the highest risk level. Before one can be sold it needs:

RCM mark on the product or its packaging, showing it’s registered to be sold in Australia.

A certificate number: power points are Level 3 equipment, so they need a Certificate of Conformity (or, in NSW, an approval number).

Listed on the national register: you can search the certificate or brand on the EESS register at eess.gov.au.

Bought locally: some pop ups from overseas marketplaces have none of these, and an electrician shouldn’t install them.

Ask us for the certificate for any model we sell and we’ll send it.

Safety switch

RCD protection is required

The Wiring Rules require 30 mA RCDs (safety switches) on all final subcircuits in homes. If your pop up is added to an older circuit without one, that altered circuit needs an RCD too. Your electrician fits it at the switchboard.

Installation

Who can install a pop up power point

Hardwired: licensed electricianAny pop up wired into the circuit is electrical work, and needs a licensed electrician in every state. In Victoria they also issue a Certificate of Electrical Safety.
Plug-in: the socket needs an electricianPlugging a pop up into an existing power point in the cupboard isn’t electrical work in NSW or Queensland. Adding that power point is, and the circuit it’s on needs RCD protection.

In New Zealand the same Wiring Rules apply to new work from 13 November 2026. Homeowners can do some of their own wiring there, but a licensed inspector must test and connect it.

Questions

Pop up power point FAQs

Are pop up power points legal in Australia?

Yes. A pop up power point is legal when the model is approved for sale in Australia, it’s installed outside the sink and cooktop zones, and any wiring is done by a licensed electrician.

How far from a sink does a power point have to be?

Under AS/NZS 3000, at least 150 mm from the side of a sink that holds 40 litres or less, and outside the zone 0.4 m above it. For sinks and tubs over 40 litres it’s 0.5 m from the side and 1 m above.

Can a power point go next to a cooktop?

Not within 150 mm of the edge of the cooktop. Further than that is fine.

Do I need an RCD for a pop up power point?

Yes. Homes need 30 mA RCDs on all final subcircuits under the current Wiring Rules, and adding a power point to an older circuit means that circuit needs one.

Can I install a pop up power point myself?

Only the parts that aren’t electrical work. Fitting a plug-in pop up and plugging it into an existing power point isn’t electrical work in NSW or Queensland, but any wiring, including a new power point in the cupboard, needs a licensed electrician.

Can I put a pop up power point in a bathroom vanity?

Bathrooms have their own zones around the basin, shower and bath. A power point can’t go in Zones 0 or 1, and in Zone 2 only an RCD-protected power point inside a cupboard is allowed. Ask your electrician to mark the zones first.

Does this apply in New Zealand?

New Zealand uses the same AS/NZS 3000, mandatory for new work from 13 November 2026. Homeowners there can do some of their own wiring, but a licensed inspector must test and connect it.

Back to blog
Seb Aroney, founder of Modern Power Solutions

About the author

Seb Aroney

Founder and Director, Modern Power Solutions

Seb has been developing pop-up outlets since 2013, and they're all Modern Power Solutions does: one specialist range for kitchens, islands and offices, sold across Australia, the US and the UK, with support and warranty handled by our own team.