This guide covers Australia. For the US, see our kitchen island outlet code guide.

Legal guide · Australia
Are Pop Up Power Points Legal in Australia? The Rules Explained
Where a pop up power point can go in your kitchen, what makes a model legal to sell, and who is allowed to install it, under the current Wiring Rules (AS/NZS 3000:2018).
By Seb Aroney, founder of Modern Power Solutions · Updated November 2026
Quick answers
Placement
How far from the sink and cooktop
Clear benchtop: outside both zones, at the end of your prep area.
Sink zone: no power point within 150 mm of the side of a sink of 40 L or less (0.5 m for bigger sinks and tubs).
Cooktop: no power point within 150 mm of the edge of the cooktop.
Tool
How far from your sink?
The zone depends on how much the sink holds. The capacity is on its spec sheet.
Sink of 40 litres or less
- Keep the power point at least 150 mm from the side of the sink.
- The zone also runs 0.4 m above the sink, so no power points on a splashback directly above it.
Sink or tub over 40 litres
- Keep the power point at least 0.5 m from the side of the sink or tub.
- The zone runs 1 m above it.
Distances are measured from the side of the sink. On an island, the best spot is usually the end of your prep area, back from where people sit.
Before you buy
What makes a pop up power point legal to sell
Power points, including pop ups with a cord that are fixed into a bench or desk, are Level 3 electrical equipment, the highest risk level. Before one can be sold it needs:
RCM mark on the product or its packaging, showing it’s registered to be sold in Australia.
A certificate number: power points are Level 3 equipment, so they need a Certificate of Conformity (or, in NSW, an approval number).
Listed on the national register: you can search the certificate or brand on the EESS register at eess.gov.au.
Bought locally: some pop ups from overseas marketplaces have none of these, and an electrician shouldn’t install them.
Ask us for the certificate for any model we sell and we’ll send it.
Safety switch
RCD protection is required
The Wiring Rules require 30 mA RCDs (safety switches) on all final subcircuits in homes. If your pop up is added to an older circuit without one, that altered circuit needs an RCD too. Your electrician fits it at the switchboard.
Installation
Who can install a pop up power point
In New Zealand the same Wiring Rules apply to new work from 13 November 2026. Homeowners can do some of their own wiring there, but a licensed inspector must test and connect it.
Questions
Pop up power point FAQs
Are pop up power points legal in Australia?
Yes. A pop up power point is legal when the model is approved for sale in Australia, it’s installed outside the sink and cooktop zones, and any wiring is done by a licensed electrician.
How far from a sink does a power point have to be?
Under AS/NZS 3000, at least 150 mm from the side of a sink that holds 40 litres or less, and outside the zone 0.4 m above it. For sinks and tubs over 40 litres it’s 0.5 m from the side and 1 m above.
Can a power point go next to a cooktop?
Not within 150 mm of the edge of the cooktop. Further than that is fine.
Do I need an RCD for a pop up power point?
Yes. Homes need 30 mA RCDs on all final subcircuits under the current Wiring Rules, and adding a power point to an older circuit means that circuit needs one.
Can I install a pop up power point myself?
Only the parts that aren’t electrical work. Fitting a plug-in pop up and plugging it into an existing power point isn’t electrical work in NSW or Queensland, but any wiring, including a new power point in the cupboard, needs a licensed electrician.
Can I put a pop up power point in a bathroom vanity?
Bathrooms have their own zones around the basin, shower and bath. A power point can’t go in Zones 0 or 1, and in Zone 2 only an RCD-protected power point inside a cupboard is allowed. Ask your electrician to mark the zones first.
Does this apply in New Zealand?
New Zealand uses the same AS/NZS 3000, mandatory for new work from 13 November 2026. Homeowners there can do some of their own wiring, but a licensed inspector must test and connect it.
Sources
- NSW Government: switches and sockets in wet areas
- HIA: changes to AS/NZS 3000:2018
- ERAC: RCD advisory note (clause 2.6.3.2.5)
- EESS: in-scope equipment and risk levels
- Energy Safe Victoria: electrical workers
- WorkSafe NZ: doing your own electrical work
This guide is general information, not legal advice. AS/NZS 3000:2018 is the standard; your licensed electrician has the final say.