Guide · Recessed outlets · USA
What Is a Recessed Outlet? Wall, Floor and Countertop Types
A recessed outlet sits set back in a wall, floor or countertop, so plugs don’t stick out. Here’s where each type works, and which countertop ones suit a kitchen.
By Seb Aroney, founder of Modern Power Solutions · Updated November 2026
Quick answers
The basics
Three kinds of recessed outlets
Recessed wall outlets
Where they suit, and what to check
Before you fit one
Check the depth in the wall cavity, especially around masonry, thin studs or a fireplace chase.
Plan the cable routing for power and any TV or data cables, so it stays neat and easy to service.
Use a licensed electrician, working to your local rules.
Recessed floor outlets
Power in the middle of the room
Floors take foot traffic and cleaning every day, so plan the floor box and its cover before the floor goes down, and have a licensed electrician fit it. This isn’t a place to cut corners.
Recessed countertop outlets
The kitchen option: pop-ups in the countertop
Why they’re worth it
Clean lines. The countertop stays clear, which matters most on stone.
Power where you use it. Right where the mixer, kettle and phone chargers live.
Less clutter. No power strips or extension cords across the countertop.
Layout freedom. Plan the kitchen around how you cook, not around where the wall outlets are.



Shop
Recessed countertop outlets we sell
Plug-inPoint Pod ConnectCloses under a disc of your own countertop, so only a slim ring shows.
HardwiredHubbell Dual-SidedSurface or flush mount, in 15 A or 20 A and 7 finishes.
Plug-inV3 motorizedCloses to a 4.37″ round lid that charges your phone.
Plug-inV15 quad-sidedPress the top and it rises; push it back down when you’re done.Reviews
What owners say about the flush look
For inspected builds
Which recessed countertop outlets are listed for countertops
The NEC only allows a receptacle in a countertop if it’s listed for countertop use (406.5(E) in the 2023 NEC, 406.14(E) in 2026), and countertop receptacles need GFCI protection. Two of the pop-ups above are listed for countertops:
Plug-in units like Point Pod Connect are installed in kitchen islands every day. UL groups them with furniture power, though, so on an inspected build show your inspector the listing before the countertop is cut. Email us and we’ll send it. On an island, the outlet goes in the countertop: under the 2023 NEC it can’t serve the countertop from the cabinet side.
General information, not legal advice. Local codes vary and your inspector has the final say.
Placement
Where to put a recessed outlet in a kitchen
Find the right recessed outlet
Answer three questions in our island finder, or email us your countertop and we’ll suggest one.

Questions
Recessed outlet FAQs
What is a recessed outlet?
An outlet set back from the surface around it, so the plug sits flush or inside the wall instead of sticking out. The common types are recessed wall outlets, floor outlets in a floor box, and recessed countertop outlets, which are usually pop-ups.
What does recessed mean?
Set back into a surface rather than standing out from it. For an outlet, it means the face sits level with, or behind, the wall, floor or countertop around it.
Are recessed outlets the same as pop-up outlets?
Not always. “Recessed” describes how the outlet sits against the surface; “pop-up” describes the mechanism. Most countertop models are both: they sit flush or nearly flush when closed and rise when you need power.
Can I use a recessed wall outlet in a countertop?
No. A receptacle installed in a countertop has to be listed for countertop use (NEC 406.5(E), or 406.14(E) in the 2026 NEC). Wall outlets aren’t. Use a countertop pop-up that’s listed for it.
What is a flush receptacle?
One whose face or cover sits level with the surface. For countertops, Hubbell’s Dual-Sided comes in a flush-mount version, set into a 4″ counterbore, and Point Pod Connect closes under a disc of your own countertop.
Is there a recessed 20 amp outlet for a countertop?
Yes. Hubbell’s Dual-Sided comes in 20 A, surface or flush mount, and is hardwired by an electrician. It’s cULus listed to UL 498 for countertops.
Do recessed countertop outlets need an electrician?
Hardwired ones do. Plug-in pop-ups plug into a GFCI-protected outlet in the cabinet below; if there isn’t one, a licensed electrician adds it.
How much space do they need under the countertop?
Point Pod Connect needs 19″ from the top of the countertop, the V3 15¾″ and the V15 9″ (11″ for the charging model). Hubbell’s Dual-Sided has a 4.7″ body.
Does a kitchen island need an outlet?
Not under the 2023 or 2026 NEC, but an island without one needs provision for adding one later, such as a box or conduit. Under the 2020 NEC they were required. The island code guide.
How far apart do backsplash outlets need to be?
Along wall countertops, no point may be more than 24 in from a receptacle, measured along the wall (NEC 210.52(C)(1)), so outlets end up no more than 4 ft apart. Islands follow their own rules.
Keep reading